Metabolights - chromatography (extended)

No description specified

SEEK ID: https://sandbox1.datahub.vib.be/templates/24

Submitter: System

Projects: Default Project

Version: 1.0.0

Group: metabolights

1 Sample type is referencing this Experiment Sample Template

ISA Level: assay - material

Organism: any

Parent Template: None

Child Templates:
  • 1 child template is hidden to you

Attributes

NameTypeDescriptionPID helpISA Tag helpUnit
protocol*StringChromatography protocol used to separate the metabolites.-protocol-
Input extract*Registered Sample List - /templates/24Extract that is used for the chromatography.---
Chromatography InstrumentControlled Vocabulary - Chromatography InstrumentChromatography Instrument, manufacturer and model-parameter_value-
Column model*Controlled Vocabulary - Column modelModel or make of the of Column used-parameter_value-
Column type*Controlled Vocabulary - Column typeType of Chromatography used.-parameter_value-
Labeled Extract NameStringIdentifier for the labeled extract.-other_material_characteristic-
Output Name*StringOutput of the chromatography.-other_material-
LabelStringIndicates a chemical or biological marker, such as a radioactive isotope or a fluorescent dye which is bound to a material in order to make it detectable by some assay technology.-other_material_characteristic-
Mobile phaseStringSpecify the liquid or gas used to transport the analytes through the chromatography column during a chromatographic separation. In liquid chromatography (LC), this typically includes a solvent or a mixture of solvents, while in gas chromatography (GC), it involves an inert carrier gas. Individual solvents should separated by a “/”, e.g. “10% H2O / 90% ACN”-parameter_value-
Gradient profile settingTextSpecify the profile of the ratio of solvents in the mobile phase used over the course of a chromatographic separation. Use notation whereby relative proportions of the eluents at a specific time point are separated by “/”, e.g. “10/90 at 1 min”. Different time points are separated by a comma. Include re-equilibration times. Example: '0/100 at 0 min, 100/0 at 6 min, 0/100 at 7 min, 0/100 at 10 min'-parameter_value-
Column temperature StringSpecify the temperature in degrees Celsius (°C) at which the chromatography column was maintained during the separation process.-parameter_value-
Flow rateStringSpecify the rate at which the mobile phase moves through the chromatography column during the separation process.-parameter_value-